Give the board a Wi-Fi address
Use the board's temporary setup network to send a lab router's details, then prove the board can reconnect after a restart.
ESP32-S3-N16R8 board
Hosts setup Wi-Fi, then joins the router.
USB data cable
Carries power, files and console messages.
Computer + USB terminal
Installs the application and reads results.
Phone or Wi-Fi laptop
Opens the local setup form.
Private lab router
2.4 GHz WPA2-Personal; temporary credentials.
mpremote on your computer. Use a private 2.4 GHz WPA2-Personal lab router with a temporary passphrase.You will do
Install three files, open a local form, observe the result and test a restart.
You will prove
The board has a router connection and an IP address, then repeats that join from its saved file.
The phone and computer may be the same laptop. Keep USB available for the setup key, redacted results and recovery. No extra circuit or external supply is needed.
One board, two network roles
AP = access point: the board hosts a temporary Wi-Fi network. STA = station: the board joins your router as a client.
Provisioning means giving a device the settings it needs. First your browser reaches the board over its setup AP. Next the board uses the submitted SSID (network name) and passphrase to join the lab router.
Setup link
Browser → board. The local page is stored on the board; internet access is unnecessary.
Router link
Board → target router. A local IP address shows local connectivity; it does not prove internet access.
Molo-Setup-C11 as the target router name. Its key gets your browser to the form; the router's passphrase gets the board onto your lab network.Install a small, known application
Place lab_config.py, softap_lab.py and main.py from this course's examples folder in one computer folder. The included example guide repeats these steps. Leave unrelated programs and configuration backed up privately.
- Connect the native USB socket. Close other serial tools. Use
mpremote connect listto find the runtime port. - If
main.pyalready exists, copy it to a new private backup filename before replacing it. If it is absent, skip that backup command. - Run the commands below from the folder containing the three files. Replace
PORTwith your actual port, such asCOM7.
mpremote connect PORT fs cp :main.py ./main-before-c11.py mpremote connect PORT fs cp lab_config.py :lab_config.py mpremote connect PORT fs cp softap_lab.py :softap_lab.py mpremote connect PORT fs cp main.py :main.py mpremote connect PORT repl
Install main.py last. In the REPL, press Ctrl+C twice, then Ctrl+D to restart and see startup messages. Rediscover the port if USB reappears under a different name.
Join the temporary setup Wi-Fi
- Read the computer's USB console. It shows
SETUP SSID: Molo-Setup-C11, a fresh SETUP KEY andhttp://192.168.4.1/. - On your phone or laptop, open Wi-Fi settings and join
Molo-Setup-C11using that temporary key. Keep the key private. - Choose to stay connected if the operating system says “No internet.” Temporarily disable an automatic switch to mobile data or another Wi-Fi network.
- Open the exact http://192.168.4.1/ address in the browser's address bar. Use HTTP, not a search box or an assumed HTTPS address.
The setup window lasts five minutes and accepts one Wi-Fi client at a time. If it expires, press RST alone to start again and read the new temporary key. A successful saved configuration goes straight to the router on later starts.
Submit the router details
Enter the target lab router's network name and temporary WPA2 passphrase. Use the exact capitalization and spaces. The example supports a 1–32 byte UTF-8 SSID and an 8–63 character printable ASCII passphrase. It does not handle open networks, enterprise login or a 64-digit raw key.
- Check that the name belongs to your 2.4 GHz lab router.
- Select Submit and try connection once. The browser sends an HTTP POST body to
/configure. - Wait for “Submission received,” then read the USB result. The form never echoes the password.
The server checks its session token and validates the same field limits again. Do not paste credentials into browser URLs, screenshots, prompts, terminal commands or support logs.
A receipt is only the first signal
The application sends and closes the HTTP response before it starts the router join. This gives the browser its receipt before the board's radio changes roles.
The station attempt lasts at most 15 seconds. The code checks sta.isconnected() and a nonzero address from sta.ifconfig()[0]. Only then does it save /lab_wifi.json and close the setup AP.
{"state": "connected", "configured": true,
"ip_assigned": true}Restart without the form
- After a
connectedresult, keep the lab router available. Leave BOOT released. - Press the upper RST button once. If the runtime port disappears, rediscover it and reopen your USB terminal.
- If you missed startup output, use Ctrl+C and Ctrl+D in the REPL to make a clean application restart while watching.
- Observe the
reconnectedresult below. Do not submit the web form again.
{"state": "reconnected", "configured": true,
"ip_assigned": true}Saved file
Exactly schema, ssid and password, with schema value 1. ML-C09 uses this same lab file format.
Keep it private
The file contains readable credentials. Do not print it or add it to Git. Protect backups, and delete lab settings when finished.
At the REPL, print(softap_lab.status()) reports only saved-state, link and IP booleans. A status read alone does not prove that a restart loaded the file.
Retry one layer at a time
| Observation | Next action |
|---|---|
| No setup network | Check USB power and the current key. A saved configuration may already have joined the router. Read USB before forcing setup. |
| No local page | Confirm the phone is still on setup Wi-Fi. Type the HTTP address manually; disable automatic Wi-Fi/mobile-data switching for the lab. |
join_failed | Rejoin setup Wi-Fi and reopen the form. Check the target SSID, temporary key, 2.4 GHz band, WPA2 mode and router availability. |
save_failed | The code disconnects STA. Keep USB, back up private files and check free filesystem space before retrying. |
setup_expired / setup_error | Return to the USB REPL. Check installation and supported firmware, then restart the application. |
A failed new attempt does not replace a previously saved valid file. On the next restart, the application tries that file first; if it cannot join, it opens setup again.
Clear the lab and start fresh
Clearing is a separate action. It removes this lab's saved settings; it does not erase the firmware or unrelated programs.
- In the USB terminal, press Ctrl+C twice to stop an active setup loop and reach
>>>. - Run the commands below. The result says
clearedandconfigured: False. - Press RST alone. The board should open a fresh setup AP and print a new key. Rejoin using that new key.
import softap_lab print(softap_lab.clear())
/lab_wifi.json and its named temporary save file. The helper also disconnects the station and closes the setup AP. It does not claim to erase credentials belonging to every other firmware or application.Open setup without deleting the saved file
import softap_lab softap_lab.run(force_setup=True)
Use this after stopping the application at the REPL. A successful new submission replaces the lab file. An unsuccessful attempt leaves the previous file available.
When the lab ends, clear the device file and remove any private computer backups you no longer need. Restore your previous main.py only from your own checked backup.
Run a complete provisioning check
- Start with no saved lab configuration. Join setup Wi-Fi and open the form.
- Use an intentionally wrong temporary lab passphrase. Confirm
join_failedafter the bounded attempt; rejoin setup if needed. - Submit correct lab details. Confirm
connectedwithip_assigned: true. The setup AP closes. - Restart with BOOT released. Confirm
reconnectedwithout resubmitting. - Clear the configuration and restart. Confirm fresh setup is available again.
Check your understanding
1. Your phone says “No internet” on setup Wi-Fi. Is setup necessarily broken?
2. The browser shows HTTP 202. Has the router join succeeded?
3. What proves that the saved file works?
Answers
1. No. The page is local to the board.
2. No. Read the link and IP result over USB.
3. A clean restart reports reconnected without another form submission.
Keep USB recovery available as you compare SoftAP with BLE and SmartConfig in the next courses.
Files for this lesson
Practice files
Keep the folder names shown below when saving files. Use these files with the matching steps in this lesson.
Keep your reference
Keep the lesson beside your practice.
Download the PDF to keep the diagrams, commands, and checkpoints close at hand. Return to the first missing observation when a step does not match.